  • Delta R 1/2/3 kVA UPS - More Value, Less TCO
  • R Series, Single Phase UPS, 1/2/3 kVA

    Technical Specifications

    Model
    R-1K / R-2K / R-3K
    Power Rating
    [1K]: 1kVA/0.9kW
     
    [2K]: 2kVA/1.8kW
     
    [3K]: 3kVA/2.7kW
    Input
     
    Nominal Voltage
    200*/208*/220/230/240 Vac
    Voltage Range
    175 ~ 280 Vac (full load)
     
    80 ~ 175 Vac (50% ~ 100% load)
    Frequency
    50/60 Hz ± 10 Hz
    Power Factor
    > 0.99 (full load)
    Current Harmonic Distortion
    < 3%
    Output
     
    Power Factor
    0.9
    Voltage
    200*/208*/220/230/240 Vac
    Voltage Regulation
    ± 1% (linear load)
    Frequency
    50/60 Hz ± 0.05 Hz
    Voltage Harmonic Distortion
    < 3% (linear load)
    Overload Capability
    < 105%: Continuous
     
    105 ~ 125%: 1 minute
     
    125 ~ 150%: 30 seconds
    Receptacle
    [1K]: IEC C13 x 4
     
    [2K]: IEC C13 x 2, IEC C19 x 1
     
    [3K]: IEC C13 x 2, IEC C19 x 1
    Efficiency
     
    AC-AC
    [1K]: 91%
     
    [2K/3K]: Up to 93%
    ECO Mode
    [1K]: 95%
     
    [2K/3K]: Up to 96%
    Battery
     
    Battery Voltage
    [1K]: 24 Vdc
     
    [2K]: 48 Vdc
     
    [3K]: 72 Vdc
    Charge Current
    4A (up to 8A with optional inbuilt charger)
    Audible Noise**
    [1K]: < 40 dB
     
    [2K/3K]: < 43 dB
    Display
    LCD display and LED indicators
    Communication Interfaces
     
    Standard
    Mini Slot x 1, RS-232 Port x 1, USB Port x 1
    Conformance
     
    Safety
    CE, BIS
    Physical
     
    Dimensions (WxDxH)
    [1K]: 440 x 335 x 88 mm
     
    [2K]: 440 x 430 x 88 mm
     
    [3K]: 440 x 430 x 88 mm
    Weight
    [1K]: 5.3 kg
     
    [2K]: 9.0 kg
     
    [3K]: 9.1 kg
    Environment
     
    Operating Temperature
    0 ~ 50°C***
    Relative Humidity
    5 ~ 95% (non-condensing)
    * When the UPS is de-rated to 90% of its capacity.
    ** If the UPS is running at <75% load and in room temperature.
    *** When the operating temperature is at 40~50°C, the UPS will be de-rated to 80% of its capacity.

    All specifications are subject to change without prior notice.